Reference | Model | Size(mm) | Step Int. (mm) | H (mm) | Stainless screws A. | Allen | Resistence | Water Tightness | Odour Tightness |
000725 | Smooth watertight 20 | 200x200 | 145 | 30 | DIN7991 A-2 M-8 | Nº 5 | - | - | - |
000723 | Smooth watertight 30 | 300x300 | 230 | 40 | DIN7991 A-2 M-10 | Nº 6 | L15 | WT | OT |
000718 | Smooth watertight 40 | 400x400 | 330 | 40 | DIN7991 A-2 M-10 | Nº 8 | L15 | WT | OT |
000719 | Smooth watertight 50 | 500x500 | 430 | 40 | DIN7991 A-2 M-10 | Nº8 | L15 | WT | OT |
000720 | Smooth watertight 60 | 600x600 | 520 | 40 | DIN7991 A-2 M-10 | Nº 8 | L15 | WT | OT |
000724 | Smooth watertight 70 | 700x700 | 620 | 40 | DIN7991 A-2 M-12 | Nº 8 | L15 | WT | OT |
* Access cover with the resistance and tightness according to EN-1253
Reference | Model | Size (mm) | Step Int. (mm) | H (mm) | Stainless screws A. | Allen |
000727 | watertight reinforced 40 | 400x400 | 320 | 55 | DIN7991 A-2 M-12 | Nº8 |
000728 | watertight reinforced 50 | 500x500 | 420 | 65 | DIN7991 A-2 M-12 | Nº8 |
000729 | watertight reinforced 60 | 600x600 | 510 | 75 | DIN7991 A-2 M-12 | Nº8 |
* The seal is used withleak-proof gasket EPDM cord cell of 8mm.
* The references 000727; 000728; 000729, include two handles for the lid.
Reference | Model | Size (mm) | Step Int.(mm) | H (mm) | H (INT.mm) | Resistence | Water Tightness | Odour Tightness |
00S730 | Watertight refillable 30 with aluminium built-in drains 10x10 | 300x300 | 240 | 70 | 40 | - | - | - |
00S731 | Watertight refillable 40 with aluminium built-in drains 10x10 | 400x400 | 240 | 70 | 40 | - | - | - |
000730 | Watertight refillable 30 | 300x300 | 240 | 70 | 40 | R50 | WT | OT |
000731 | Watertight refillable 40 | 400x400 | 340 | 70 | 40 | M125 | WT | OT |
000732 | Watertight refillable 50 | 500x500 | 430 | 80 | 30 | R50 | WT | OT |
000733 | Watertight refillable 65 | 650x650 | 585 | 80 | 30 | R50 | WT | OT |
* Each lid includes two handles
* Four screws made from stainless steel, Allen 6, Din 912 A-2 M8
* Access cover with the resistance and tightness according to EN-1253.
EN-1253 STANDARD.
RESISTENCE.
Class L15: Areas driven over by light traffic such as commercial spaces and public areas.
Class R50: Areas driven over by traffic, such as industrial buildings and factories.
Class M12: Areas driven over by traffic, such as multi-storey car parks, factories and workshops
TIGHTNESS.
Wt class: water tightness. The covers must prevent the entry of rainwater that does not exert hydrostatic pressure.
Ot class: odor tightness. The covers must prevent the exit of stale air.